Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
1.
J Neurosurg ; : 1-8, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701528

RESUMO

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483647

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos
3.
J Neurointerv Surg ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238006

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

4.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862717

RESUMO

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
5.
Transl Stroke Res ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165289

RESUMO

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

6.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35868856

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Embolização Terapêutica/métodos
7.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35483912

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Doenças das Artérias Carótidas/terapia
8.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36066701

RESUMO

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
10.
Radiology ; 304(2): 372-382, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438564

RESUMO

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/terapia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
11.
J Neurosurg ; : 1-8, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35120326

RESUMO

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

12.
J Neurointerv Surg ; 14(6): 546-550, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34226193

RESUMO

BACKGROUND: M2 segment occlusions represent approximately one-third of non-lacunar ischemic stroke and can lead to permanent neurological deficits. Various techniques are available for mechanical thrombectomy beyond the circle of Willis, but data evaluating their effectiveness and safety are lacking. METHODS: A retrospective review of patients with ischemic stroke undergoing mechanical thrombectomy for M2 occlusions from 13 centers in North American and Europe was performed. Tandem or multiple-territory occlusions were excluded. The primary outcome was 90-day modified Rankin Scale and reperfusion rates across stent-retriever, direct aspiration and combined techniques. RESULTS: There were 465 patients (mean age 71.48±14.03 years, 53.1% female) with M2 occlusions who underwent mechanical thrombectomy. Stent-retriever alone was used in 133 (28.6%), direct aspiration alone in 93 (20.0%) and the combined technique in 239 (51.4%) patients. Successful reperfusion was achieved with the combined technique in 198 (82.2%; OR 2.6 (1.1-6.9)), with stent-retriever alone in 112 (84.2%; OR 9.2 (1.9-44.6)) and with direct aspiration alone in 62 (66.7%; referencecategory). Intraprocedural subarachnoid hemorrhages (iSAH) were 36 (7.7%) and were more likely to occur in patients treated with the stent-retrievers (OR 5.0 (1.1-24.3)) and combined technique (OR 4.6 (1.1-20.9)). Good clinical outcome was achieved in 260 (61.8%) patients, while 59 (14.0%) patients died. Older age, higher baseline NIHSS (National Institutes of Health Stroke Scale), parenchymal hemorrhage and iSAH were associated with poor outcome while successful recanalization and higher baseline ASPECTS (Alberta Stroke Program Early CT Score) were associated with good outcome. No differences were found among the three techniques in terms of clinical outcome. CONCLUSION: Stent-retrievers and a combined approach for M2 occlusions seem more effective than direct aspiration, but with higher rates of iSAH. This leads to no detectable difference in clinical outcome at 3 months.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Círculo Arterial do Cérebro/diagnóstico por imagem , Círculo Arterial do Cérebro/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/efeitos adversos , Trombectomia/métodos , Resultado do Tratamento
13.
Stroke ; 53(2): e47-e49, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915737
14.
Adv Radiat Oncol ; 6(2): 100644, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33732962

RESUMO

PURPOSE: Postoperative stereotactic radiosurgery (SRS) is associated with up to 30% risk of subsequent leptomeningeal disease (LMD). Radiographic patterns of LMD (classical sugarcoating [cLMD] vs. nodular [nLMD]) in this setting has been shown to be prognostic. However, the association of these findings with neurologic death (ND) is not well described. METHODS AND MATERIALS: The records for patients with brain metastases who underwent surgical resection and adjunctive SRS to 1 lesion (SRS to other intact lesions was allowed) and subsequently developed LMD were combined from 7 tertiary care centers. Salvage radiation therapy (RT) for LMD was categorized according to use of whole-brain versus focal cranial RT. RESULTS: The study cohort included 125 patients with known cause of death. The ND rate in these patients was 79%, and the rate in patients who underwent LMD salvage treatment (n = 107) was 76%. Univariate logistic regression demonstrated radiographic pattern of LMD (cLMD vs. nLMD, odds ratio: 2.9; P = .04) and second LMD failure after salvage treatment (odds ratio: 3.9; P = .02) as significantly associated with ND. The ND rate was 86% for cLMD versus 68% for nLMD. Whole-brain RT was used in 95% of patients with cLMD and 52% with nLMD. In the nLMD cohort (n = 58), there was no difference in ND rate based on type of salvage RT (whole-brain RT: 67% vs. focal cranial RT: 68%, P = .92). CONCLUSIONS: LMD after surgery and SRS for brain metastases is a clinically significant event with high rates of ND. Classical LMD pattern (vs. nodular) and second LMD failure after salvage treatment were significantly associated with a higher risk of ND. Patients with nLMD treated with salvage focal cranial RT did not have higher ND rates compared with WBRT. Methods to decrease LMD and the subsequent high risk of ND in this setting warrant further investigation.

15.
J Neurointerv Surg ; 13(11): 1012-1016, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33483455

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is approved in the USA for treatment of unruptured wide-neck bifurcation aneurysms. However, the safety and effectiveness of the WEB device in the treatment of ruptured intracranial aneurysms is not clear. We aim to evaluate the perioperative safety and effectiveness of the WEB device in patients with ruptured intracranial aneurysms. METHODS: This retrospective study, conducted at eight centers in the USA, included patients with ruptured intracranial aneurysms treated with the WEB device in the setting of subarachnoid hemorrhage (SAH). Safety outcomes included intraoperative complications such as vessel perforation, thromboembolic events, and postoperative hemorrhagic or thromboembolic complications based on radiologic imaging. The primary effectiveness outcome was adequate (complete and neck remnant) aneurysm occlusion, according to the Raymond-Roy classification. RESULTS: A total of 91 patients with 94 ruptured intracranial aneurysms were included (mean age 57.7±15.2 years; 68.1% women; 82.9% wide-necked). Aneurysms were located in the anterior communicating artery (42/94, 44.6%), middle cerebral artery (16/94, 17%), and basilar artery (15/94, 16%). Adequate occlusion was achieved in 48.8% (41/84) and 80.0% (40/50) at discharge and last follow-up (mean of 3.4 months), respectively. At discharge, procedural-related morbidity was 3.3% (3/91) and there was no procedure-related mortality. No re-rupture or delayed aneurysm rupture was observed. CONCLUSIONS: This study demonstrates the perioperative safety and effectiveness of the WEB device for the treatment of patients with ruptured intracranial aneurysms in the setting of SAH, with low periprocedural morbidity and mortality. Long-term follow-up is warranted.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
16.
World Neurosurg ; 144: e500-e506, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32891835

RESUMO

BACKGROUND: Spinal arthrodesis is a commonly performed spinal operation. Spinal arthrodesis can be complicated by pseudoarthrosis and resultant hardware failure. Static magnetic fields (SMF) have the ability to improve bone fusion. We seek to assess the feasibility of the construction and implantation of a lumbar interbody cage equipped with a SMF in a caprine model. METHODS: Six skeletally mature female Boer goats underwent a lateral approach for placement of an interbody graft at lumbar (L) 1-2 and 3-4. The goats were divided into 2 groups of 3 animals. The interbody graft contained a neodymium iron boron magnet in the experimental group and a nonmagnetic titanium sham in the control group. Both groups contained a synthetic bone graft. Blinded radiographic and histologic evaluation was performed at predetermined timepoints to assess degree of bony fusion and osseointegration. RESULTS: All 6 goats underwent successful placement of lumbar interbody grafts. At the 1-month postoperative computed tomography, 1 goat in the experimental group and 1 goat in the control group were noted to have dislodged their intervertebral cage. Qualitative radiographic and histologic evaluation identified enhanced bone formation, bone density, and osteointegration of the graft in the experimental group. CONCLUSIONS: A spinal interbody cage containing a neodymium iron boron magnet for the production of a local SMF is feasible. Preliminary data suggests enhanced bone formation, bone density, and osseointegration of the graft.


Assuntos
Magnetoterapia/instrumentação , Fusão Vertebral/instrumentação , Animais , Cabras , Vértebras Lombares , Osseointegração , Projetos Piloto , Próteses e Implantes , Distribuição Aleatória
17.
Neurosurgery ; 87(6): 1252-1261, 2020 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-32629474

RESUMO

BACKGROUND: The Pipeline Embolization Device (PED; Medtronic) has been used off-label for the treatment of challenging posterior circulation aneurysms. Data on this modality are primarily limited to small retrospective single-center series. OBJECTIVE: To assess safety and efficacy of this treatment by establishing an international, multicenter collaboration. METHODS: Consecutive posterior circulation aneurysms treated with the PED from 2012 to 2019 across 11 neurovascular centers were retrospectively reviewed. Baseline demographics, aneurysm and treatment characteristics, complications, occlusion status, and functional outcome were assessed. RESULTS: There were 149 posterior circulation aneurysms treated with PED in 146 patients. A total of 24 (16.4%) patients presented with subarachnoid hemorrhage. Most aneurysms were dissecting/blister (36.2%) in morphology, followed by saccular (35.6%) and fusiform (28.2%). The most common locations were the vertebral (51.7%) and basilar arteries (22.8%). Complete or near-complete occlusion (>90%) was achieved in 90.9% of aneurysms at a median follow-up of 12 mo. Dissecting/blister aneurysms were most likely to occlude (P = .06). Symptomatic neurologic complications occurred in 9.4% of aneurysms, associated with larger size, ruptured presentation, presentations with brain stem compression, cranial nerve palsy, or stroke. Favorable functional outcome (modified Rankin Score 0-2) was achieved in 86.2% of patients. There were 6 fatalities of which 4 occurred in aneurysmal subarachnoid hemorrhage patients. CONCLUSION: This multicenter study shows that PED for the treatment of posterior circulation is preferentially used for the treatment of fusiform and dissecting/blister aneurysm morphologies. Despite the challenges presented by these less-common morphologies, flow diversion may be performed with a neurologic complication rate of about 10% and favorable long-term aneurysm occlusion rates.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Estudos de Coortes , Embolização Terapêutica/efeitos adversos , Seguimentos , Humanos , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
18.
World Neurosurg ; 143: e294-e302, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32711134

RESUMO

BACKGROUND: Anticoagulant therapy is common and complicates the operative management of acute and mixed-density subdural hematomas (SDHs). The risk of reoperation inferred by anticoagulant (AC) medication and the ability of reversal agents to reduce hemorrhagic complications in patients presenting with AC-associated SDHs are not fully understood. METHODS: Data were collected for 288 consecutive patients treated with craniotomy or craniectomy for evacuation of an acute or mixed-density SDH between 2012 and 2017 at 2 academic institutions. Primary end points were reoperation within 30 days and functional outcome at discharge. Groups were compared based on AC use. Logistic regression models were used to identify predictors of reoperation and functional outcome at discharge. RESULTS: Forty-six patients on ACs and 242 with no AC history were analyzed. All patients on AC underwent AC reversal before hematoma evacuation. Reoperation rates between groups were not significantly different (10.9% vs. 12.4%; P = 1.00); however, time to reoperation was significantly shorter in those on ACs (0.8 ± 1.1 days vs. 6.8 ± 10.4 days; P = 0.04). Aspirin use was independently associated with the need for reoperation (odds ratio, 3.05; confidence interval, 1.30-7.19; P = 0.01). Patients taking ACs were significantly older, had more medical comorbidities and were more likely to have a higher modified Rankin Scale score at discharge. CONCLUSIONS: Anticoagulant use was not associated with an increased reoperation rate, suggesting that reversal of AC may have eliminated the hemorrhagic risk conferred by these medications. Patients on ACs were significantly older, harbored more medical comorbidities, and had a worse functional outcome at discharge.


Assuntos
Anticoagulantes/administração & dosagem , Hematoma Subdural Crônico/cirurgia , Reoperação/tendências , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fatores de Coagulação Sanguínea/administração & dosagem , Estudos de Coortes , Feminino , Hematoma Subdural Crônico/induzido quimicamente , Hematoma Subdural Crônico/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Clin Neurol Neurosurg ; 194: 105842, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32325400

RESUMO

OBJECTIVE: Digital subtraction angiography is the gold standard for diagnosis of vascular pathology. The value of angiography of non-target vessels following mechanical thrombectomy for the treatment of acute ischemic stroke (AIS) is unknown. PATIENTS AND METHODS: Consecutive patients treated with mechanical thrombectomy for AIS due to large vessel occlusion (LVO) at an academic institution between February 2016 and December 2018 were retrospectively reviewed. Demographic information, clinical data, and procedure details were recorded. Descriptive statistics were used to evaluate the utility of non-target vessel angiography. RESULTS: One hundred and fifty-six patients presenting with AIS due to LVO were treated with 159 mechanical thrombectomy procedures. Median age was 71.5 years. Ninety-one (57.2%) procedures were followed with a diagnostic cerebral angiogram of non-target vessels. Previously unknown findings were identified in 4 (4.4%) procedures. Management change due to the non-target vessel angiogram finding occurred in 3 (3.3%) cases and included one contralateral mechanical thrombectomy. No complications occurred as a result of the non-target vessel angiogram. CONCLUSION: Angiographic imaging of non-target vessels following mechanical thrombectomy identified previously unknown vascular pathology in 4.4% of procedures and resulted in a clinical management change in 3.3% of cases.


Assuntos
Angiografia Cerebral , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/cirurgia , Procedimentos Neurocirúrgicos/métodos , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
20.
J Neurosurg ; 134(3): 961-970, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32217800

RESUMO

OBJECTIVE: Coverage of the anterior spinal artery (ASA) ostia is a source of considerable consternation regarding flow diversion (FD) in vertebral artery (VA) aneurysms due to cord supply. The authors sought to assess the association between coverage of the ASA, posterior spinal artery (PSA), or lateral spinal artery (LSA) ostia when placing flow diverters in distal VAs and clinical outcomes, with emphasis on cord infarction. METHODS: A multicenter retrospective study of 7 institutions in which VA aneurysms were treated with FD between 2011 and 2019 was performed. The authors evaluated the risk of ASA and PSA/LSA occlusion, associated thromboembolic complication, complications overall, aneurysm occlusion status, and functional outcome. RESULTS: Sixty patients with 63 VA and posterior inferior cerebellar artery aneurysms treated with FD were identified. The median aneurysm diameter was 7 mm and fusiform type was the commonest morphology (42.9%). During a procedure, 1 (61.7%) or 2 (33.3%) flow diverters were placed. Complete occlusion was achieved in 71.9%. Symptomatic thromboembolic complications occurred in 7.4% of cases and intracranial hemorrhage in 10.0% of cases. The ASA and PSA/LSA were identified in 51 (80.9%) and 35 (55.6%) complications and covered by the flow diverter in 29 (56.9%) and 13 (37.1%) of the procedures, respectively. Patency after flow diverter coverage on last follow-up was 89.2% for ASA and 100% for PSA/LSA, not significantly different between covered and noncovered groups (p = 0.5 and p > 0.99, respectively). No complications arose from coverage. CONCLUSIONS: FD aneurysm treatment in the posterior circulation with coverage of ASA or PSA/LSA was not associated with higher rates of occlusion of these branches or any instances of cord infarction.


Assuntos
Infarto Cerebral/etiologia , Procedimentos Neurocirúrgicos/efeitos adversos , Artéria Vertebral/cirurgia , Idoso , Estudos de Coortes , Embolização Terapêutica , Procedimentos Endovasculares , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Medula Espinal/irrigação sanguínea , Tromboembolia/complicações , Tromboembolia/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...